Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Transbound Emerg Dis ; 69(5): 2649-2655, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-1571105

ABSTRACT

SARS-CoV-2 variation represents a serious challenge to current COVID-19 vaccines. Recent reports suggest that B.1.351 and other variants may escape the neutralization activity of the antibodies generated by current vaccines. Ninety-nine healthcare workers undertaking BNT162b2 mRNA vaccination were sampled at baseline, on the day of the second dose, and 14 days after the latter. Neutralization activity against SARS-CoV-2 B.1, B.1.1.7 and B.1.351 was investigated using a Vero-E6 model. Eleven of the study participants had prior infection with SARS-CoV-2. Neutralization titers against the B.1 and the B.1.1.7 variants were not statistically different and were significantly higher than titers against the B.1.351 variant across pre-exposed and non-pre-exposed vaccinated individuals (p < .01). While all vaccinated individuals presented neutralizing antibodies against B.1 and B 1.1.7 after the second dose, 14% were negative against B.1.351 and 76% had low titers (1/201/80). Pre-exposed vaccinated individuals showed higher titers than non-pre-exposed after the first (median titers of 1/387 versus 1/28, respectively) and the second doses (1/995 versus 1/703, respectively). As high as 72% of the pre-exposed vaccines presented titers >1/80 after a single dose, while only 11% of non-exposed vaccinated individuals had titers >1/80. BNT162b2 mRNA-induced antibodies show a lower in vitro neutralizing activity against B.1.351 variant compared to neutralization against B.1.1.7 or B.1 variants. Interestingly, for individuals pre-exposed to SARS-CoV-2, one dose of BNT162b2 mRNA may be adequate to produce neutralizing antibodies against B.1.1.7 and B.1, while two doses of BNT162b2 mRNA provide optimal neutralizing antibody response against B.1.351 too.


Subject(s)
COVID-19 , SARS-CoV-2 , Animals , Antibodies, Neutralizing , Antibodies, Viral , BNT162 Vaccine , COVID-19/prevention & control , COVID-19/veterinary , COVID-19 Vaccines , Humans , Membrane Glycoproteins , Neutralization Tests/veterinary , RNA, Messenger/genetics , SARS-CoV-2/genetics , Spike Glycoprotein, Coronavirus , Viral Envelope Proteins/genetics
2.
Transbound Emerg Dis ; 69(5): 3073-3076, 2022 Sep.
Article in English | MEDLINE | ID: covidwho-1381142

ABSTRACT

We monitored the severe acute respiratory syndrome coronavirus 2 antibody response in seven dogs and two cats by using two multispecies ELISA tests, plaque reduction neutralisation test and virus neutralization. SARS-CoV-2 neutralizing antibodies in pets persisted up to 10 months since the first positive testing, thus replicating observations in COVID-19 human patients.


Subject(s)
COVID-19 , Dog Diseases , Animals , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/veterinary , Dogs , Humans , Neutralization Tests/veterinary , SARS-CoV-2
3.
J Virol Methods ; 286: 113979, 2020 12.
Article in English | MEDLINE | ID: covidwho-786045

ABSTRACT

Feline coronaviruses (FCoV) are members of the alphacoronavirus genus that are further characterized by serotype (types I and II) based on the antigenicity of the spike (S) protein and by pathotype based on the associated clinical conditions. Feline enteric coronaviruses (FECV) are associated with the vast majority of infections and are typically asymptomatic. Within individual animals, FECV can mutate and cause a severe and usually fatal disease called feline infectious peritonitis (FIP), the leading infectious cause of death in domestic cat populations. There are no approved antiviral drugs or recommended vaccines to treat or prevent FCoV infection. The plaque reduction neutralization test (PRNT) traditionally employed to assess immune responses and to screen therapeutic and vaccine candidates is time-consuming, low-throughput, and typically requires 2-3 days for the formation and manual counting of cytolytic plaques. Host cells are capable of carrying heavy viral burden in the absence of visible cytolytic effects, thereby reducing the sensitivity of the assay. In addition, operator-to-operator variation can generate uncertainty in the results and digital records are not automatically created. To address these challenges we developed a novel high-throughput viral microneutralization assay, with quantification of virus-infected cells performed in a plate-based image cytometer. Host cell seeding density, microplate surface coating, virus concentration and incubation time, wash buffer and fluorescent labeling were optimized. Subsequently, this FCoV viral neutralization assay was used to explore immune correlates of protection using plasma from naturally FECV-infected cats. We demonstrate that the high-throughput viral neutralization assay using the Celigo Image Cytometer provides a robust and efficient method for the rapid screening of therapeutic antibodies, antiviral compounds, and vaccines. This method can be applied to various viral infectious diseases to accelerate vaccine and antiviral drug discovery and development.


Subject(s)
Coronavirus Infections/veterinary , Coronavirus, Feline/isolation & purification , High-Throughput Screening Assays/veterinary , Image Cytometry/methods , Neutralization Tests/methods , Animals , Cat Diseases/diagnosis , Cat Diseases/virology , Cats , Cell Line , Coronavirus Infections/diagnosis , Coronavirus Infections/virology , Feline Infectious Peritonitis/diagnosis , Feline Infectious Peritonitis/virology , High-Throughput Screening Assays/methods , Image Cytometry/veterinary , Neutralization Tests/veterinary , Viral Load
SELECTION OF CITATIONS
SEARCH DETAIL